Spec ledger
Every number the solver uses, where it came from, and what we rejected. Last run 2026-11-01.
13products passed
5products quarantined
78fields from the primary source
11fields from secondary sources
4panels with an assumed temp coefficient
What failed verification, and why?
| Product | Reasons | Source checked |
|---|---|---|
| EcoFlow RIVER 3 Plus |
| us.ecoflow.com |
| Anker SOLIX F3000 |
| Amazon listing |
| EcoFlow 400W Portable |
| us.ecoflow.comAmazon listing |
| BLUETTI 350W Portable |
| bluettipower.com |
| HQST Ultra-Light 200W |
| hqsolarpower.com |
Which panel specs are verified?
| Rated power | 220 W | us.ecoflow.com“220W (±5W) Front/175W Rear” |
|---|---|---|
| Voc | 21.5 V | us.ecoflow.com“21.5V (Vmp 18.4V)” |
| Vmp | 18.4 V | us.ecoflow.com“Vmp 18.4V” |
| Isc | 12.4 A | us.ecoflow.com“12.4A (Imp 11.9A) Front Side” |
| Imp | 11.9 A | us.ecoflow.com“Imp 11.9A” |
| β (Voc) | −0.40 %/°C | Assumed: not published by the maker |
| Connector | MC4 | us.ecoflow.comsecondary“Photovoltaic connectors (adapted to MC4 connectors)” |
| Rated power | 100 W | us.ecoflow.com“100 W(+/-5W)” |
|---|---|---|
| Voc | 20.3 V | us.ecoflow.com“20.3 V” |
| Vmp | 17.1 V | us.ecoflow.com“17.1 V” |
| Isc | 6.3 A | us.ecoflow.com“6.3 A” |
| Imp | 5.9 A | us.ecoflow.com“5.9 A” |
| β (Voc) | -0.33 %/°C | us.ecoflow.com“-0.33%/°C” |
| Connector | MC4 | us.ecoflow.comsecondary“Photovoltaic connectors (adapted to MC4 connectors)” |
| Rated power | 45 W | us.ecoflow.com“45W (±3W)” |
|---|---|---|
| Voc | 25.6 V | us.ecoflow.com“25.6V” |
| Vmp | 21.9 V | us.ecoflow.com“21.9V” |
| Isc | 2.06 A | us.ecoflow.com“2.06A” |
| Imp | 2 A | us.ecoflow.com“2.0A” |
| β (Voc) | −0.40 %/°C | Assumed: not published by the maker |
| Connector | DC5521 | us.ecoflow.com“Type-C” |
| Rated power | 200 W | jackery.com“200W±5%” |
|---|---|---|
| Voc | 22 V | jackery.com“22V±5%” |
| Vmp | 18 V | jackery.com“18V±5%” |
| Isc | 12.5 A | jackery.com“12.5A±5%” |
| Imp | 11.5 A | jackery.com“11.5A±5%” |
| β (Voc) | -0.27 %/°C | jackery.com“-(0.27±0.03)%/°C” |
| Connector | DC8020 | Amazon listing“a DC8020 * 1 port” |
| Rated power | 200 W | renogy.com“200 W” |
|---|---|---|
| Voc | 21.6 V | renogy.com“21.6V” |
| Vmp | 18.8 V | renogy.com“18.8V” |
| Isc | 11.3 A | renogy.com“11.3A” |
| Imp | 10.6 A | renogy.com“10.6A” |
| β (Voc) | −0.40 %/°C | Assumed: not published by the maker |
| Connector | MC4 | renogy.com“MC4” |
| Rated power | 100 W | renogy.com“100 W±3%” |
|---|---|---|
| Voc | 24.4 V | renogy.com“24.4 V” |
| Vmp | 20.7 V | renogy.com“20.7 V” |
| Isc | 5.16 A | renogy.com“5.16 A” |
| Imp | 4.84 A | renogy.com“4.84 A” |
| β (Voc) | −0.40 %/°C | Assumed: not published by the maker |
| Connector | MC4 | renogy.comsecondary“Solar Connectors” |
Which station limits are verified?
| Capacity | 1024 Wh | us.ecoflow.com“1024 Wh” |
|---|---|---|
| AC continuous | 1800 W | us.ecoflow.com“6 outlets, 1800W total (Surge 3600W)” |
| AC surge | 3600 W | us.ecoflow.com“6 outlets, 1800W total (Surge 3600W)” |
| Solar Charging input 1 | 11 to 60 V, 15 A, 500 W | us.ecoflow.com“2 ports, DC Charge Input, 11V-60V 500W Max*2” |
| Solar Charging input 2 | 11 to 60 V, 15 A, 500 W | us.ecoflow.com“2 ports, DC Charge Input, 11V-60V 500W Max*2” |
| Solar Charging input 1 connector | XT60i | ridgewatt.comsecondary“DELTA 3 Plus XT60i” |
| Solar Charging input 2 connector | XT60i | ridgewatt.comsecondary“DELTA 3 Plus XT60i” |
| Solar Charging input 1 current limit | 15 A | Secondary source: the maker’s page publishes none |
| Solar Charging input 2 current limit | 15 A | Secondary source: the maker’s page publishes none |
| Capacity | 4096 Wh | us.ecoflow.com“4096Wh” |
|---|---|---|
| AC continuous | 4000 W | us.ecoflow.com“4000W, 6000W with X-boost” |
| AC surge | 8000 W | us.ecoflow.com“8000W” |
| High-PV Input | 30 to 150 V, 15 A, 1600 W | us.ecoflow.com“High-PV Input: 30V-150V⎓, 15A, 1600W Max” |
| Low-PV Input | 11 to 60 V, 20 A, 1000 W | us.ecoflow.com“Low-PV Input: 11V-60V⎓, 20A, 1000W Max” |
| High-PV Input connector | XT60 | offgridstores.comsecondary“EcoFlow Solar to XT60i Charging Cable” |
| Low-PV Input connector | XT60i | offgridstores.comsecondary“EcoFlow Solar to XT60i Charging Cable” |
| Capacity | 499 Wh | us.ecoflow.com“499Wh capacity and 500W output.” |
|---|---|---|
| AC continuous | 500 W | us.ecoflow.com“120V 50Hz/60Hz, 500W (Surge 1000W)” |
| AC surge | 1000 W | us.ecoflow.com“120V 50Hz/60Hz, 500W (Surge 1000W)” |
| Solar Input | 11 to 50 V, 13 A, 220 W | us.ecoflow.com“11-50V, 13A, 220W Max” |
| Solar Input connector | XT60i | us.ecoflow.com“Works best with RIVER 2/RIVER 2 Max/RIVER 2 Pro” |
| Capacity | 1070 Wh | jackery.com“30.4Ah/35.2V DC (1070 Wh)” |
|---|---|---|
| AC continuous | 1500 W | jackery.com“1500W Rated, 3000W Surge peak” |
| AC surge | 3000 W | jackery.com“1500W Rated, 3000W Surge peak” |
| DC 8mm Input 1 | 12 to 60 V, 10.5 A, ? W | jackery.com“(2x) DC 8mm Ports: 12-16V(Working Voltage)⎓8A Max,” |
| DC 8mm Input 2 | 12 to 60 V, 10.5 A, ? W | jackery.com“(2x) DC 8mm Ports: 12-16V(Working Voltage)⎓8A Max,” |
| DC 8mm Input 1 connector | DC8020 | jackery.com“DC8020 input port” |
| DC 8mm Input 2 connector | DC8020 | jackery.com“DC8020 input port” |
| Capacity | 2042 Wh | jackery.com“45.6Ah/44.8V DC (2042 Wh)” |
|---|---|---|
| AC continuous | 2200 W | jackery.com“2200W Rated, 4400W Surge peak” |
| AC surge | 4400 W | jackery.com“2200W Rated, 4400W Surge peak” |
| DC Input 1 (DC 8mm) | 11 to 60 V, 12 A, ? W | jackery.com“(2x) 2 x DC 8mm Ports: 11-16V⎓8A Max, Double to 8A Max;16-60V⎓12A, Double to 21A/400W Max” |
| DC Input 2 (DC 8mm) | 11 to 60 V, 12 A, ? W | jackery.com“(2x) 2 x DC 8mm Ports: 11-16V⎓8A Max, Double to 8A Max;16-60V⎓12A, Double to 21A/400W Max” |
| DC Input 1 (DC 8mm) connector | DC8020 | jackery.com“DC 8mm Ports” |
| DC Input 2 (DC 8mm) connector | DC8020 | jackery.com“DC 8mm Ports” |
| Capacity | 1152 Wh | bluettipower.com“1,152Wh (AC180)” |
|---|---|---|
| AC continuous | 1800 W | bluettipower.com“1800W In Total” |
| AC surge | 2700 W | bluettipower.com“2700W” |
| Solar Input | 12 to 60 V, 10 A, 500 W | bluettipower.com“500W Max., VOC 12-60VDC, 10A” |
| Solar Input connector | XT60 | bluettipower.comsecondary“20A MC4 to XT60 Solar Charging Cable” |
| Capacity | 2073.6 Wh | bluettipower.com“2,073.6Wh (54 Ah)” |
|---|---|---|
| AC continuous | 2600 W | bluettipower.com“2600W continuous output” |
| AC surge | Not published | Not published by the maker |
| Solar Input | 12 to 60 V, 20 A, 1000 W | bluettipower.com“Solar Input 1,000W Max., 12V to 60V, 20A Max.” |
| Solar Input connector | XT60 | bluettipower.comsecondary“20A MC4 to XT60 Solar Charging Cable” |